似空科学仪器(上海)有限公司>> JetetchPro-CuNisene化学芯片开封机CuProtect

Nisene化学芯片开封机CuProtect

返回列表页
  • Nisene化学芯片开封机CuProtect
收藏
举报
参考价 面议
具体成交价以合同协议为准
  • 型号 JetetchPro-Cu
  • 品牌 其他品牌
  • 厂商性质 代理商
  • 所在地 上海市
在线询价 收藏产品 加入对比 查看联系电话

更新时间:2025/07/29 08:58:07浏览次数:2057

联系我们时请说明是化工仪器网上看到的信息,谢谢!

同类优质产品

更多产品

产品简介

价格区间 面议 仪器种类 微流控芯片系统
应用领域 电子/电池 具有铜线防护的化学芯片开封系统 JetEtch Pro CuProtect
JetEtch CuProtect是在基础版的JetEtch Pro上增加了专li技术以保护芯片内部的铜线在化学蚀刻过程中不受到损害。在化学蚀刻的过程中,JetEtch CuProtech会在芯片的铜线表面形成离子层,从而?;ね弑磺克崴础C拦鶱isene科技集团有限公司从事集成电路失效分析的自动开封装置研发超过40年,拥有多项电化学及微波等离子开封机技术的专li。

详细介绍

CuProtect工艺 - 美国专li8,945,343 B2-用施加的电压解封装。 

     具有铜线防护的化学芯片开封系统 ---- JetEtch Pro CuProtect

     Protecting Those Sensitive Copper Wires.

      It just got easier.

        With the price of gold at an all-time high, a current trend in the manufacturing of integrated circuits is the shift from gold to copper bond wires. With this shift, the failure analyst of these processors is now challenged to successfully attain package decapsulation by use of traditional methods.

主要特征(Features):

    Patented Bias Technology 

    Advanced Software 

    Affordable 

    All JetEtch Pro Features 
 

The Old Methods.

        Historically, one would use an automated chemical decapsulation system to etch samples with copper wires — with minimal success. Even with a low-temperature nitric and sulfuric acid mixture, and even in combination with laser pre-opening, this process works to an extent, but is largely unreliable. When faced with a limited number of field failures, which is a common scenario in a failure analysis laboratory setting, less reliable processes can’t be counted on to deliver satisfactory failure analysis and visual inspection results.

The Solution.

        To support manufacturers in making this shift so that failure analysis can still be performed on their most advanced and cutting edge products which now use copper wire bonding, Nisene Technology Group has developed a version of its new JetEtch Pro decapsulation system that is specifically designed to handle the processing of this sensitive material: the JetEtch Pro CuProtect — the latest in a series of innovative solutions for the failure analysis industry from Nisene.

The Process.

CuProtect Principle Illustration        Using a proprietary and patented process, the JetEtch Pro CuProtect applies a bias to the solution being pumped to the sample in the process chamber. This bias creates a condition in which negatively-charged sulfate ions are attracted and temporarily bond to the surface of the copper wire while the sample is being etched. This temporary sulfate ion coating protects the copper wires from corrosion while the sample undergoes the etching process.

        The image to the right illustrates the operating principal behind the technique. Click on the image to open a larger version in a new window.

        In less sophisticated systems relying solely on low temperature etching, positively-charged hydrogen ions are attracted to the copper wires, thereby making the wires susceptible to pitting, cracking, breaking, and many other undesirable anomalous artifacts that greatly affect or even squelch completely the ability to perform failure analysis after the etching process. The Nisene Technology Group CuProtect system solves this problem.

The Results.

        As illustrated in the images below, the advanced bias application process yields results that are unmatched in the industry.

Protected Copper Wires Protected Copper Wires Protected Copper Wires 

        If you would like to see more examples of samples etched with the CuProtect, please contact us.
 

The Software.

        “Surely something like this must be complicated to use and difficult to understand — right?” you ask. The answer to that is “of course not!” The system appears on the outside to be the same as the JetEtch Pro, but there is an added line in its decapsulation programming menu that allows the user to change the value of the applied bias. The range is 0 V (off or no bias) to 20.0 V, selectable in .1 V increments. The other differences between the CuProtect system and the JetEtch Pro — both in hardware and software — are hidden inside the system, so operating the CuProtect is exactly like JetEtch Pro and virtually transparent to a user. That is to say: learning curve is very small. There’s no need to learn anything new other than how much voltage to apply to your sample while it is etching.

JetEtch Operation Screen JetEtch Pro CuProtect Operation Screen

        One additional parameter line. Not much to learn here!

 