国产日产欧美精品-亚洲国产综合久久精品-色综合色国产热无码一-亚洲欧美日本国产,免费观看一区二区三区_在线观看片A免费不卡观看_亚洲а∨天堂久久精品_99久无码中文字幕一本久道

| 注冊| 產品展廳| 收藏該商鋪

行業(yè)產品

13917975482
當前位置:
似空科學儀器(上海)有限公司>> JetetchPro-CuNisene化學芯片開封機CuProtect

Nisene化學芯片開封機CuProtect

返回列表頁
  • Nisene化學芯片開封機CuProtect
收藏
舉報
參考價 面議
具體成交價以合同協(xié)議為準
  • 型號 JetetchPro-Cu
  • 品牌 其他品牌
  • 廠商性質 代理商
  • 所在地 上海市
在線詢價 收藏產品 加入對比 查看聯(lián)系電話

更新時間:2023/05/23 21:19:03瀏覽次數(shù):2035

聯(lián)系我們時請說明是化工儀器網上看到的信息,謝謝!

同類優(yōu)質產品

更多產品

產品簡介

價格區(qū)間 面議 儀器種類 微流控芯片系統(tǒng)
應用領域 電子/電池 具有銅線防護的化學芯片開封系統(tǒng) JetEtch Pro CuProtect
JetEtch CuProtect是在基礎版的JetEtch Pro上增加了專li技術以保護芯片內部的銅線在化學蝕刻過程中不受到損害。在化學蝕刻的過程中,JetEtch CuProtech會在芯片的銅線表面形成離子層,從而保護銅線被強酸所腐蝕。美國Nisene科技集團有限公司從事集成電路失效分析的自動開封裝置研發(fā)超過40年,擁有多項電化學及微波等離子開封機技術的專li。

詳細介紹

CuProtect工藝 - 美國專li8,945,343 B2-用施加的電壓解封裝。 

     具有銅線防護的化學芯片開封系統(tǒng) ---- JetEtch Pro CuProtect

     Protecting Those Sensitive Copper Wires.

      It just got easier.

        With the price of gold at an all-time high, a current trend in the manufacturing of integrated circuits is the shift from gold to copper bond wires. With this shift, the failure analyst of these processors is now challenged to successfully attain package decapsulation by use of traditional methods.

主要特征(Features):

    Patented Bias Technology 

    Advanced Software 

    Affordable 

    All JetEtch Pro Features 
 

The Old Methods.

        Historically, one would use an automated chemical decapsulation system to etch samples with copper wires — with minimal success. Even with a low-temperature nitric and sulfuric acid mixture, and even in combination with laser pre-opening, this process works to an extent, but is largely unreliable. When faced with a limited number of field failures, which is a common scenario in a failure analysis laboratory setting, less reliable processes can’t be counted on to deliver satisfactory failure analysis and visual inspection results.

The Solution.

        To support manufacturers in making this shift so that failure analysis can still be performed on their most advanced and cutting edge products which now use copper wire bonding, Nisene Technology Group has developed a version of its new JetEtch Pro decapsulation system that is specifically designed to handle the processing of this sensitive material: the JetEtch Pro CuProtect — the latest in a series of innovative solutions for the failure analysis industry from Nisene.

The Process.

CuProtect Principle Illustration        Using a proprietary and patented process, the JetEtch Pro CuProtect applies a bias to the solution being pumped to the sample in the process chamber. This bias creates a condition in which negatively-charged sulfate ions are attracted and temporarily bond to the surface of the copper wire while the sample is being etched. This temporary sulfate ion coating protects the copper wires from corrosion while the sample undergoes the etching process.

        The image to the right illustrates the operating principal behind the technique. Click on the image to open a larger version in a new window.

        In less sophisticated systems relying solely on low temperature etching, positively-charged hydrogen ions are attracted to the copper wires, thereby making the wires susceptible to pitting, cracking, breaking, and many other undesirable anomalous artifacts that greatly affect or even squelch completely the ability to perform failure analysis after the etching process. The Nisene Technology Group CuProtect system solves this problem.

The Results.

        As illustrated in the images below, the advanced bias application process yields results that are unmatched in the industry.

Protected Copper Wires Protected Copper Wires Protected Copper Wires 

        If you would like to see more examples of samples etched with the CuProtect, please contact us.
 

The Software.

        “Surely something like this must be complicated to use and difficult to understand — right?” you ask. The answer to that is “of course not!” The system appears on the outside to be the same as the JetEtch Pro, but there is an added line in its decapsulation programming menu that allows the user to change the value of the applied bias. The range is 0 V (off or no bias) to 20.0 V, selectable in .1 V increments. The other differences between the CuProtect system and the JetEtch Pro — both in hardware and software — are hidden inside the system, so operating the CuProtect is exactly like JetEtch Pro and virtually transparent to a user. That is to say: learning curve is very small. There’s no need to learn anything new other than how much voltage to apply to your sample while it is etching.

JetEtch Operation Screen JetEtch Pro CuProtect Operation Screen

        One additional parameter line. Not much to learn here!

 