1. PERFORMANCE
1) Measuring range :0.02-0.5%
Number of pump strokes 1(100ml)
2) Sampling time :4 minutes/1 pump stroke
3) Detectable limit :20 ppm
4) Shelf life :2 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Orange→Brown
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:15% RSD-high:15%
3. CHEMICAL REACTION
Chromium oxide is reduced.
CH3CH2CH3+Cr6++H2SO4→Cr3+
4. CALIBRATION OF THE TUBE
GAS CHROMATOGRAPHY
5. INTERFERENCE AND CROSS SENSITIVITY
0.5
0.4
0.3
0.2
0.1
0.02
%
GAS To pump
125SA PROPANE
Substance Interference Coexistence
Toluene Similar stain is produced. Higher readings are given.
Hexane 〃〃
Trichloroethylene 〃〃
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(ppm) (32°F) (50°F) (68°F) (86°F) (104°F)
0.50 0.40 0.45 0.50 0.50 -
0.40 0.33 0.37 0.40 0.35 -
0.30 0.26 0.28 0.30 0.28 0.42
0.25 0.21 0.23 0.25 0.22 0.32
0.20 0.17 0.19 0.20 0.16 0.26
0.15 0.13 0.14 0.15 0.22 0.19
0.10 0.09 0.10 0.10 0.11 0.13
0.05 0.05 0.06 0.05 0.05 0.05