ENGINEERING STANDARDS
Issue No: 2 MGR ES:
TITLE: Generic Electrical/Electronic Component Test Date: 25th March 2005
- 32 -
- Printed Copy is Uncontrolled - Check Issue is Current -
Specific requirements:
Applicable components See Table 2
Mounting position In vehicle-mounted attitude with associated brackets and components
Test duration 30 cycles
Electrical operation: Permanent battery feed only
Water temperature 80°C
Water pressure 100 o 3 Bar
Water discharge angle 35° o 5p
Distance of jet nozzle 80 to 100mm
from test sample
Spray time 10s for each accessible spatial direction (when installed in the vehicle),
followed by a 10s break
Assessment: The test sample must be fully capable of functioning